Part Number: M81044/12-18-3
SAE AS81044/12 Cable M81044/12-18-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-20-93
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-20-97
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-24-3
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-24-94
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-20-90
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-22-90
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-16-3
SAE AS81044/12 Cable M81044/12-16-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-20-3
SAE AS81044/12 Cable M81044/12-20-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-22-3
SAE AS81044/12 Cable M81044/12-22-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-24-2
SAE AS81044/12 Cable M81044/12-24-3 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M81044/12-14-3
SAE AS81044/12 Cable M81044/12-14-2 Lightweight Wall Cross-Linked PVDF Wire Conductor: Soft Annealed Tin Plated Copper, Stranded Operating Temperature: 150 deg C Operating Voltage: 600 Volts Insulation: Irradiation Cross-Linked Extruded Polyalkene PVDF Jacket: Clear Irradiation Cross-Linked Extruded Polyvinylidene Flouride (PVDF) with a Wall Thickness of 0.003 +/-.001...
Part Number: M22759/32-12-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-14-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-16-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-18-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-20-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-22-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-24-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts
Part Number: M22759/32-26-3
SAE AS22759/32 Cable Lightweight Wall Cross-Linked ETFE Wire Cable Insulation: Single Layer Irradiation Cross-Linked Extruded ETFE Conductor: Soft Annealed Tin Plated Copper (/32) Operating Temperature: 150 degC/200 degCOperating Voltage: 600 Volts